Paul Wrote;
I have a very persistent problem with Windows 95 OSR2 and I would
appreciate some help in resolving it. Every time I exit control panel it
goes to a blue screen stating the following message:
"Fatal Exception 0E has occurred at 0028:C0286E19 in VXD IFSMGR(4) +
0000D4F1
The current application will be terminated."
According to Microsoft technet (PSS ID Number: Q175211), the following
could relate to you... Good luck
douglas
====
If you have installed a scanner on your computer, the following symptoms
may occur:
- When you attempt to open or close Control Panel, you may receive the
following error message:
A fatal exception 0E has occurred at 0028:C029F7A1 in VXD
IFSMGR(04)
+ 0000D4F1.
The current application will be terminated.
After receiving this error message, you can still use Control Panel,
but
the Speaker icon may no longer appear on the taskbar. This behavior
may
also occur in Safe mode.
- When you start Windows 95, you may receive the following error
message:
A fatal exception 0E has occurred at 028:C0282dB0 in VxD
IFSMGR(03) +
0000 CF7C
The current application will be terminated.
CAUSE
=====
This behavior can occur if the Vhpscand.vxd file is located in the
Windows\System folder instead of the Windows\System\Iosubsys folder.
RESOLUTION
==========
To resolve this behavior, follow these steps:
1. Click Start, point to Programs, and then click Windows Explorer.
2. On the Tools menu, point to Find, and then click Files Or Folders.
3. In the Named box, type "vhpscand.vxd" (without quotation marks), and
then click Find Now.
4. If the Vhpscand.vxd file is located in the Windows\System folder,
right-click the Vhpscand.vxd file, and then click Cut.
5. Right-click the Windows\System\Iosubsys folder, and then click Paste.
6. Restart your computer.
Douglas Brown
PC Support
Bombardier Services, Defence
|