Albert,

With sighted assistance you could install this.  If your existing thermostat 
has the connections labeled "O", "Y", "G" etc. then you would move the wires 
from the old thermostat to same labeled terminals on talking thermostat.  In 
some instillations, a jumper wire may need to be added between some 
additional terminals.  The package contains printed wiring diagrams for 
various configurations.

I believe the VIP1000 has been discontinued.

Below are the specifications:

TalkingThermostats.com
Comfort Solutions for persons who are blind or have low vision
VIP Series of residential Talking Thermostats that promotes independent 
living
The VIP series is the first digital thermostat with audio playback of day, 
time, indoor temperature,
temperature setting and programming instructions so blind and low vision 
users can precisely
and easily manage their indoor comfort.
Yes, the VIP "talks" to you! When you press the day/time, weekend or weekday 
schedule buttons,
you are voice prompted to enter the correct settings.
Press the REPORT button to hear
"day of the week, time, indoor temperature and the thermostat setting"
Press the UP or DOWN arrow buttons to
"raise or lower the temperature and hear the new temperature setting"
Press the HELP button to
"obtain a telephone number to call for questions regarding your thermostat"
Email: [log in to unmask] Tel: 1-800-838-8860 763-591-9557 Fax: 
763-544-7166
The Standard VIP 1007 and VIP 2007 Talking Thermostats
All New VIP 3000 Universal Talking Thermostat
The VIP 1007
Controls single stage conventional 24 Vac gas, oil and
electric furnaces and single stage electric air conditioning
systems.
The VIP 2007
Controls single stage compressor heat pump systems with
auxiliary heat. The VIP 2007 can also control one or two
stage conventional 24 Vac gas, oil and electric furnaces
and single stage electric air conditioners.
The NEW VIP 3000 is a full featured universal multi-stage
talking thermostat that can control most 24 Vac AC and
Heating Systems including the newest multi-stage (up to
3H and 2C) gas, oil and electric furnaces, air conditioners
and heat pump / dual fuel (hybrid) systems with 1 or 2
stage compressors and auxiliary heat. The VIP 3000 has
enhanced speech functions and optional auto-changeover

VIP Series Talking Thermostat Features, Model Selection and Specifications

Features

.
Very User Friendly -built in voice instructions guides the user in setting 
the day, time, temperature and weekly settings.
..
Built in Loud Speaker - announces in a human voice, the current day, time, 
room temperature, set point and programming
instructions when the appropriate button is pressed.
..
Audio CD - with complete audio instructions to operate and program the VIP 
is included with each thermostat. Also
included on the disk is a text file of the instructions.

. Push button Convenience - easy to use control panel, receive voice 
confirmation after each button press.
.
Off Wall programming - program your VIP before mounting to the wall.
. Program Choice - programmable 5+2 setback schedule or non-programmable 
mode.
..
Multiple programs - up to four time and temperature settings per weekday and 
separate weekend settings in the
5+2 programmable setback mode.

.
Models for most applications -VIP 1007 for conventional 1 stage heating / 1 
stage cooling, VIP 2007 for 1 stage
compressor heat pump systems with auxiliary heat or conventional 2 stage 
heating / 1 stage cooling systems, VIP
3000 can control all systems mentioned above in additional to most of the 
newest multi-stage (up to 3H and 2C) gas,
oil and electric furnaces, air conditioners and heat pump / dual (Hybrid) 
fuel systems with 1 or 2 stage compressors
and auxiliary heat. The VIP 3000 as enhanced speech functions and optional 
auto-changeover.
. Freeze protection - turns on heating system at 40 degrees if thermostat is 
off or is inoperative.
. Memory Backup - assures that all programmed data will be retained in the 
event of a power failure.
.
Low Battery Alarm - announces when the battery is low.
.
LCD Display - shows current time, temperature, set point temperature and 
system status for the sighted person.
Everything that is displayed is also spoken.
Model Information

VIP 1000 Series (current model is the VIP 1007)

VIP 1007: The VIP 1007 controls single stage conventional 24 Vac gas, oil 
and electric furnaces and single stage
electric air conditioning systems. The VIP 1007 replaces most 2, 3, 4 and 5 
wire wire analog and digital thermostats
including the very popular "round" model.

VIP 2000 Series (current model is the VIP 2007)

VIP 2007: The VIP 2007 controls single stage compressor heat pump systems 
with auxiliary heat. Please note, the V I P
2007 can only be used with heat pump systems that do not use an outdoor 
thermostat. The VIP 2007 can also control
one or two stage conventional 24 Vac gas, oil and electric furnaces and 
single stage electric air conditioners.

VIP 3000 Series (current model is the VIP 3000)

VIP 3000: The VIP 3000 is a universal multi-stage talking thermostat that 
can control most 24 Vac Heating and Air
Conditioning Systems including the newest multi-stage (up to 3H and 2C) gas, 
oil and electric furnaces, air conditioners
and heat pump / dual fuel (Hybrid) systems with 1 or 2 stage compressors and 
auxiliary heat. Has enhanced speech
functions (talking Fan and System buttons) and optional auto-changeover.

Specifications

Flammability............................UL 94 V-0
Power Source.............................4 AA batteries

Color.........................................White
Output Load Ratings..................1.5 amps max @ 24 Vac

DisplayTemperature Ratings

 VIP 1007-VIP 2007....LCD 1.0 X 2.0"
Operating.........................40º F to 90º F (4º C to 32º C) VIP 
3000.........LCD 1.4 X 2.3"

 Setpoint Range......................50º F to 90º F (10º C to 32º C) System 
Switch
Accuracy ...................± 2º F VIP 1007-VIP 2007....3 position (Heat - 
off - Cool)
VIP 3000.........5 position (Off - Cool - Heat - Aux - Auto)

 Differential.. ................. 1 to 3º F
Fan Switch...............................2 position (on - auto)

Humidity Rating........................5% to 90% RH, non-condensing
Freeze Protection.....................40º F if thermostat is off or 
inoperative

Wiring Connections...................Screw terminals
Short Cycle Protection.............5 minute

Case Material...........................High Impact ABS Plastic
Dimensions..............................7.0"w X 4.0"h X 1.5"d

The EZRA Group LLC / Talking Thermostats.com

PO Box 27145 Golden Valley, MN 55427
E-mail: [log in to unmask] Tel: 1-800-838-8860 763-591-9557 Fax: 
763-544-7166

Howard #3 