Hi Jose,
In version 3.12 you must register all memory above 16 meg in the
Autoexec.ncf file. Check out document 2947903 of Novell's knowledgebase to
get the full details.
Good Luck,
Cheryl
>From: "Jose E. Dominguez" <[log in to unmask]>
>Reply-To: PCBUILD - Personal Computer Hardware discussion List
><[log in to unmask]>
>To: [log in to unmask]
>Subject: [PCBUILD] Server Blues
>Date: Tue, 13 Jul 1999 22:16:06 -0400
>
>I upgraded the RAM on a server running Netware 3.12 and here's what
>happened.
>
>I removed the 32MB in SIMMs that were on the board, and I added two
>128MB of PC-100, the voltage is
>correct.
>
>The system boots, counts the whole 256MB and proceeds. The SCSI BIOS is
>loaded, the hard drive is identified, DOS is loaded, DOS goes through
>it's routine (the last two lines on the autoexec.bat are, cd server.312
>then server) then this exact message comes up.
>
>Insufficient memory to run Netware 386
>(requires at least 3 megabytes of extended memory)
>
>C:\server.312>
>
>And it just sits there.
>
>If I take out the 256MB and install the 32MB it proceeeds and loads
>server. the RAM is good, that is not it.
>
>Any suggestions? I know nothing about Novell so please be very precise
>with instructions on what to do.
>
>TIA,
>
>Jose
>
> PCBUILD's List Owner's:
> Bob Wright<[log in to unmask]>
> Drew Dunn<[log in to unmask]>
_______________________________________________________________
Get Free Email and Do More On The Web. Visit http://www.msn.com
Visit our website regularly for FAQs,
articles, how-to's, tech tips and much more