Skip Navigational Links
LISTSERV email list manager
LISTSERV - LISTSERV.ICORS.ORG
LISTSERV Menu
Log In
Log In
LISTSERV 17.5 Help - BLIND-HAMS Archives
LISTSERV Archives
LISTSERV Archives
Search Archives
Search Archives
Register
Register
Log In
Log In

BLIND-HAMS Archives

For blind ham radio operators

BLIND-HAMS@LISTSERV.ICORS.ORG

Menu
LISTSERV Archives LISTSERV Archives
BLIND-HAMS Home BLIND-HAMS Home

Log In Log In
Register Register

Subscribe or Unsubscribe Subscribe or Unsubscribe

Search Archives Search Archives
Options: Use Forum View

Use Monospaced Font
Show Text Part by Default
Show All Mail Headers

Message: [<< First] [< Prev] [Next >] [Last >>]
Topic: [<< First] [< Prev] [Next >] [Last >>]
Author: [<< First] [< Prev] [Next >] [Last >>]

Print Reply
Subject:
Re: How to Correctly Configure AC Log to Interface with Kenwood TS-2000
From:
David W Wood <[log in to unmask]>
Reply To:
[log in to unmask]
Date:
Thu, 19 Jun 2014 08:24:51 +0100
Content-Type:
text/plain
Parts/Attachments:
text/plain (73 lines)
From memory, I seem to recall the default BAUD rate for the TS2000 is 4800,
but I sold mine over five years ago.

73

David W Wood 

-----Original Message-----
From: For blind ham radio operators [mailto:[log in to unmask]]
On Behalf Of Richard B McDonald
Sent: Thursday, June 19, 2014 1:53 AM
To: [log in to unmask]
Subject: How to Correctly Configure AC Log to Interface with Kenwood TS-2000

Hi!

 

In AC Log, under the Settings > Rig Interface menu, there are various fields
that need to be correctly set so that AC Log interfaces with the PC.  I do
not think the issue relates to the cable connection; see item 2, below.
Following are my questions:

 

1.  The first field is Select Rig.  There are two Kenwood types - "Kenwood"
and "Kenwood 2."  Which is the right one for a Kenwood TS-2000?

 

2.  The next field asks for the Com Port.  This is set to "COM3"; which I am
sure is right because I use both the ARCP-2000 and the MCP2000 applications
successfully with that same Com Port.

 

3.  Next is baud rate.  Every other application (like ARCP-2000 and MCP2000)
uses 9600 bps; so that is what I think this field should be set to.

 

4.  Next, there are three fields for Parity, Data Bits and Stop Bits.  These
are defaulted to "None", "8" and "2", respectively.  I have a sneaky
suspicion that the Stop Bits should instead be "1."  Maybe there is more as
well.

 

5.  Next are two fields for Connection and Polling; which I believe are
correctly set at "RTS" and "2 seconds", respectively.

 

6.  Then there is a field for how the Mode is determined; which seems
correctly defaulted to "Rig."

 

7.  Finally, there are two fields about which Commands to use to read the
frequency and Mode.  I believe that these are correctly defaulted to "fa;"
and "md;", respectively.

 

So, what are the correct settings for all of this?  Right now, AC Log does
not seem to be correctly interfacing with my PC.

 

73,

Richard KK6MRH