True, Alan, but this was referencing the AL-811 amps.

----- Original Message ----- 
From: "Alan R. Downing" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, March 20, 2014 11:32 AM
Subject: Re: employing a CO


> Remember that what meters display differs on different amps.  For example,
> my Henry 5K Classic has a plate current meter and a meter that switches
> between plate voltage and grid current.  Some amps have separate meters 
> for
> each parameter.
>
> Alan/KD7GC
>
>
> Alan R. Downing
> Phoenix, AZ
>
>
> -----Original Message-----
> From: For blind ham radio operators [mailto:[log in to unmask]]
> On Behalf Of Steve
> Sent: Thursday, March 20, 2014 8:16 AM
> To: [log in to unmask]
> Subject: Re: employing a CO
>
> The second meter is grid current oly.  The first meter is switchable 
> between
>
> plate current and voltage.
> ----- Original Message ----- 
> From: "Steve Dresser" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Wednesday, March 19, 2014 3:06 PM
> Subject: Re: employing a CO
>
>
>> So what does that second meter monitor?
>>
>> Steve
>>
>> ----- Original Message ----- 
>> From: "Steve" <[log in to unmask]>
>> To: <[log in to unmask]>
>> Sent: Wednesday, March 19, 2014 11:35
>> Subject: Re: employing a CO
>>
>>
>>> Well, you probably could do that but I don't know if there would be a
>>> convenient way to mount the switch.  I chose not to monitor the other
>>> meter,
>>> since the main meter has a switch to monitor plate voltage or current.
>>>
>>> ----- Original Message ----- 
>>> From: "Michael Ryan" <[log in to unmask]>
>>> To: <[log in to unmask]>
>>> Sent: Tuesday, March 18, 2014 5:15 PM
>>> Subject: Re: employing a CO
>>>
>>>
>>>> Thanks steve for that link.=20
>>>> Could essentially a device be built with lets say, 2 connections, a =
>>>> switch and both grid and plate current be monitored?=20
>>>>
>>>> Mike=20=
>>> 