Thanks, Tom. ... This is a good suggestion and sure worth a try.
Do you think having the ladder line more horizontal than vertical could also
be throwing things off?
73 from Tom Behler: KB8TYJ
----- Original Message -----
From: <[log in to unmask]>
To: <[log in to unmask]>
Sent: Thursday, December 20, 2007 8:57 PM
Subject: Re: g5rv question
> Tom, if you've connected the ladder line directly to the rg8 or whatever
> you're
> using, you need a choke. Get a 5 or 6in piece of some sort of plastic
> pipe and
> wrap ten or so turns of the rg8 around it very neatly and tape it into
> place. A
> transformer choke doesn't work for this but my guess is that will take
> care of
> your problem. The idea with moving the ladder line is to keep it away
> from
> metal. Whether you're using 300 or 450 ohm the impedance changes when its
> around metal, particular if it gets wet.
>
> Tom
>
>
> Tom Brennan KD5VIJ, CCC-A/SLP
> web page http://titan.sfasu.edu/~g_brennantg/sonicpage.html
>
>