On 26 Jan 00, at 16:44, Dharam Bhardwaj wrote:
> I need to move the NT4 Server on a P166 to another computer that I am
> assembling. Most components including the scsi controller will be
> different. I was thinking of taking an image of the hard drive and
> copying it to the new computer. Will this work or will I have to do a
> rebuild? Or will I have to create the new machine as a BDC first? I have
> not done this before. Downtime is not an issue.
> Regards,
> Dharam
If the existing server is a PDC, then the way you replace it is to
bring its replacement onto the network as a BDC, sync it with the
PDC, and then promote it and demote the old PDC. This means there is
a point where both machines are operational on the net, which limits
how much of their hardware can be shared....