The main meter that reads grid or plate voltage that is selectable with the 
front panel switch.

If you get the terminals reversed, the pitch on your VCO will go down 
instead of up, just make sure you check it before you button up the amp. 
And, treat the thing with respect, there's a lot of voltage that can be 
floating around, around 1800 volts I think on the plates.  Don't trust the 
fact that the bleeder resistors are supposed to drain it.

Steve, K8SP
----- Original Message ----- 
From: "Steve Dresser" <[log in to unmask]>
To: <[log in to unmask]>
Sent: Monday, March 17, 2014 8:01 PM
Subject: Re: Tuning the 811H


> Steve,
>
> Which meter did you put the VCO across?  Should both meter terminals be
> isolated from ground?
>
> Steve
>
> ----- Original Message ----- 
> From: "Steve" <[log in to unmask]>
> To: <[log in to unmask]>
> Sent: Monday, March 17, 2014 17:15
> Subject: Re: Tuning the 811H
>
>
>> Personally, I don't tune mine for maximum output.  If you do, you may be
>> drawing too much grid current.  I have a voltage-controlled oscillator
>> hooked across the meter on mine.   I tune the plate for a dip and turn 
>> the
>> load control just until the output starts increasing.
>>
>> Steve, K8SP
>> 