On Tuesday, August 31, 1999 2:27 PM, al steele <[log in to unmask]>wrote:
> Hello
>
> I lost the manual and need the INIT code for a Modem - Sportster 14400.
>
> I need the Hayes ATM0 equiv to - turn off noise when dialing code
>
> thankx
Try "AT and F1" and bookmark this web site,
http://www.accessone.com/support/modems/usr.html, and
http://www.globalnet.co.uk./support/modini.htm#usr, if it is a USR modem.
Hayes Modems
Hayes modems should be quite happy with at&f
US Robotics
Universal USR init string. Try this one first; at&f1
Sportster Voice 33600 at&f1s32=16s56.7=1s34=128 or at&f1s32=16s33=32
US Robotics Sportster 28.8 Vi at&f1s54=96
US Robotics Sportster Si 14.4 at&fw2&c1&d2&k3&q5s7=60s36=7s46=138s48=7s
Strings for various USR modems at&f1s7=90s27=32, at&f1s27=32s54.5=1,
at&f&a3&b1&h1&r2, atz
Walter R. Worth
[log in to unmask]